Refine On (Hebei) Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of flash point analyzer in China. If you're going to wholesale durable flash point analyzer, welcome to get quotation from our factory. All customized products are with high quality and competitive price.
Application Scenarios
The flash point analyzer utilizing a precision processor to control heating temperatures, it is suitable for testing various substances-such as industrial lubricants, gear oils, hydraulic fluids, heat transfer oils, and compressor oils-to determine their flash point. The flash point is a critical indicator of a liquid's fire hazard; measuring it is essential for controlling operating temperatures and assessing whether the oil has deteriorated or become contaminated with impurities.


Technical Parameters
|
Item |
Specification |
|
Measurement range |
40°C–400°C |
|
Temperature detection |
Platinum resistance |
|
Accuracy |
±1°C |
|
Repeatability |
±3°C (≤150°C), ±5°C (>150°C) |
|
Self-test functions |
Probe, electric igniter, cooling fan, printer, heating furnace |
|
Ignition method |
Electric ignition |
|
Cooling method |
Air cooling |
|
Power |
≤700W |
|
Ambient temperature |
5°C–40°C |
|
Ambient humidity |
≤90% |
|
Power supply |
AC 220V ±10% |
|
Frequency |
50Hz ±5% |
|
Dimensions |
Main unit: 430 × 400 × 260 (mm) |
|
Instrument weight |
Main unit: 24kg |


Product Features
High level of automation: parameters can be preset to allow for fully automatic flash point testing and recording of results.
Large color touchscreen display ensures intuitive operation and clear, easy-to-read information.
Flash point values and other relevant test data can be printed on-site.
Electric ignition system offers enhanced safety and exceptional durability.
FAQ
Q: What is the appropriate amount of oil sample to use for testing?
A: The sample level in the open cup should be slightly below the fill mark, as the sample volume expands as the temperature rises. The amount of sample used should be kept consistent for each test.
Q: How should the Flash Point Analyzer be maintained if it is not used for an extended period?
A: Maintenance focuses primarily on the oil cup and the flash point sensor, as both are prone to accumulating oily residue that can affect measurement accuracy; petroleum ether can be used to clean the ring.
Q: When performing repeat tests on an oil sample, to what temperature should it be cooled?
A: Ensure that the temperatures of both the heating plate and the sample are below 56°C. Excessively high temperatures can affect the measurement results.
Hot Tags: flash point analyzer, China flash point analyzer manufacturers, suppliers, factory, industrial transformer oil tester, Insulating Oil Dielectric Loss Resistivity Tester, insulating oil moisture analyzer, Transformer Oil Acidity Tester, transformer oil conductivity tester, transformer oil evaluation system