Industrial Hipot Testers for High-Voltage Insulation Testing

 

 

Reliable dielectric withstand testing equipment designed for power transformers, switchgear, cables, and electrical machinery. Built with heavy-duty HV transformers and microprocessor-controlled tripping systems to ensure strict compliance with IEC, IEEE, and ASTM insulation standards.

 

 
  • High Voltage Phasing Tester
    The transmitters are mainly used to determine whether the line is energized, thus enabling the measurement of the line's phase and frequency.
  • Circuit Breaker Analyzer
    The Circuit Breaker Analyzer Named by function: High-voltage switch mechanical characteristic tester, high-voltage switch operating characteristic tester, high-voltage switch comprehensive
  • Switchgear Tester
    High-voltage circuit breakers play a crucial role in power systems, undertaking both control and protection tasks. Their performance directly impacts the safe operation of the power system, and the
  • AC Hipot Tester
    The performance of electrical equipment plays a crucial role in the power system, and the most important performance indicator is the withstand voltage rating. Our company's AC Hipot Tester can be
  • AC Withstand Voltage Tester
    The AC Withstand Voltage Tester, also known as a test transformer, is mainly used for power testing. It can perform withstand voltage level tests on a range of power equipment involved in the power
  • DC High Voltage Generator
    The DC High Voltage Generator is mainly used for DC withstand voltage testing of power equipment and leakage current testing of zinc oxide surge arresters. It can output voltages from 60kV to over
  • DC Hipot
    The DC Hipot is a portable test transformer with a voltage boosting capability up to 200kV. It consists of a control box and a test transformer. The control box can be either portable or roller-type
  • DC Hipot Tester
    The DC Hipot Tester is a commonly used electrical testing device manufactured by our company. Some electrical equipment must undergo power frequency withstand voltage testing during factory delivery,
  • Primary Current Injection Tester
    Model: NRG1000Adopt beautiful and generous PVC panelThe measurement accuracy is 0.5High power, small volume, strong load capacity
  • VLF Hipot Tester
    Model: NRG30C/50C/80CEasy to operate: simple wiring, fool operation.Large test range: 0.1Hz, 0.05Hz and 0.02hz multi frequency selection, large test range.Small volume and light weight: it is very
  • DC High Voltage Tester
    • Model: NRG60/80/100/120 DC High Voltage Tester . • Adopts high-frequency PWM closed-loop regulation for stable output.. • Output voltage range: 60 kV / 80 kV / 100 kV / 120 kV (model-dependent),
  • Smart Dc High Voltage Tester
    The NRG60Z/80Z/ 100Z/120Z Smart DC High Voltage Tester series is designed for DC withstand voltage and preventive insulation testing. . Key features include:. • 7-inch 800×480 full-color touchscreen
First 12 Last
 

Product Series

 
 
01
 

AC Hipot Test Set (Dry-Type / Oil-Immersed / Inflatable)

Voltage Range: Up to 300 kV AC
Capacity: 5 kVA - 500 kVA
Primary Use: Standard factory acceptance testing (FAT) for distribution transformers, insulators, and switchgear.

 
02
 

AC/DC Dual-Output Hipot Tester

Voltage Range: Up to 300 kV AC / 400 kV DC
Capacity: 5 kVA - 100 kVA
Primary Use: Field insulation diagnostics for underground cables, DC power supply units, and capacitive loads.

 
03
 

Automated Microprocessor-Controlled Hipot Test Bench

Voltage Range: Customized per rating (10 kV - 500 kV)
Features: Automated voltage ramping, leakage current graph plotting, RS485/Modbus data integration, PLC remote control.
Primary Use: Automated transformer production lines and accredited third-party testing laboratories.

High Voltage Phasing Tester

 

 

Technical Specifications

 

 

Specification Parameter

Dry-Type AC Hipot Set

Oil-Immersed AC/DC Set

Automatic PLC Test System

Output Voltage Range

0 - 50 kV AC

0 - 100 kV AC / 0 - 120 kV DC

0 - 300 kV AC (Customizable)

Rated Output Capacity

5 kVA - 50 kVA

10 kVA - 100 kVA

20 kVA - 500 kVA

Output Voltage Accuracy

plus-minus 1.5% Full Scale

plus-minus 1.0% Full Scale

plus-minus 0.5% Full Scale

Leakage Current Measurement Range

0.1 mA - 500 mA

0.1 mA - 1000 mA (DC)

0.01 mA - 2000 mA

Tripping Response Time

less than 20 ms

less than 15 ms

less than 10 ms

Output Waveform Distortion (THD)

less than or equal to 3% (Resistive/Inductive); less than or equal to 1.5% for low-partial-discharge customized test benches. (Note: Capacitive load testing may require optional series damping reactors)

less than or equal to 2.5%

less than or equal to 1.5%

Duty Cycle

30 min ON / 15 min OFF (at max load)

Continuous operation at 80% load

Continuous heavy-duty

Input Voltage Options

220V / 380V / 415V (50/60 Hz)

220V / 380V / 415V (50/60 Hz)

380V / 480V 3-Phase

Operating Temperature

-10 degrees C to +50 degrees C

-20 degrees C to +55 degrees C

-10 degrees C to +50 degrees C

 

Standards & Calibration
 

Design & Safety Compliance:

Built in accordance with IEC 60060-1 (High-voltage test techniques), IEC 60076 (Power transformers), and IEEE Std 4.

Calibration Traceability:

Every unit is supplied with a factory routine test report traceable to ISO/IEC 17025 accredited calibration standard laboratories.

afety Interlocks:

SPhysical zero-start protection (prevents HV energization unless the regulator is at zero position), emergency trip buttons, external safety cage contact loops, and automated grounding discharge rods for capacitive loads.

 

Applications

Power & Distribution Transformers:

Insulation integrity testing between primary/secondary windings and ground core during manufacturing and overhaul.

High-Voltage Switchgear & GIS:

Dielectric withstand verification across open contacts and busbar compartments.

Power Cables & Accessories:

High-voltage DC withstand testing and leakage current profiling on XLPE insulated cables.

Electrical Motors & Generators:

Stator winding insulation quality assurance for OEM production lines.

 

Configuration & Manufacturing Quality

 

 

Core Components & Dielectric Integrity: High-permeability cold-rolled silicon steel cores with optimized gradient winding structures. Dry-type units feature vacuum epoxy casting, while oil-immersed models undergo multi-stage vacuum degasification and oil filling to maintain partial discharge levels below 10 pC at rated voltage.

Control Console Modular Architecture: Digital display meter units separated from high-voltage step-up transformers via isolated control cabinets to guarantee operator safety.

Factory Testing & QC Inspection: Each hipot system undergoes 120% over-voltage endurance testing, short-circuit breakdown tripping tests, and thermal imaging checks prior to shipment.

 

 

Our Certificate

 

 

ISO9001, ISO14001, ISO45001 

productcate-1-1
productcate-1-1
productcate-1-1
productcate-1-1

 

 

FAQ

 

 

Q: What capacity (kVA) rating do I need for my hipot testing application?

A: Required capacity depends directly on the test voltage (V) and the capacitive reactance (C) of the test object (I = 2 * pi * f * C * V). For example, testing long power cables or large transformers requires higher kVA due to large capacitive charging currents. Contact our engineering team with your specimen details to calculate exact kVA requirements.

Q: What is the difference between dry-type, oil-immersed, and SF6 gas-filled transformers?

A: Dry-type units utilize epoxy resin casting; they are lightweight and maintenance-free, ideal for field use up to 50 kV. Oil-immersed units offer superior heat dissipation and higher voltage limits (up to 300 kV+) for heavy factory testing. SF6 inflatable units provide compact size and high dielectric strength without oil contamination risks.

Q: Does the system include automatic over-current and zero-start protection?

A: Yes. The control console prevents high-voltage output startup if the voltage regulator is not at the zero position. Furthermore, if the specimen breaks down and leakage current exceeds the set threshold, the main circuit breaker trips within 10-20 milliseconds.

Q: Can the hipot tester perform both AC and DC insulation tests?

A: Our dual-output series includes a built-in high-voltage silicon rectifying stack. Switching between AC and DC output is managed either via a high-voltage selector rod or through terminal reconnects on the control panel.

Q: What documentation is supplied with the equipment?

A: Each unit ships with an Operating Manual, Factory Routine Test & Inspection Certificate, Schematics Wiring Diagram, and a Calibration Report. Third-party ISO/IEC 17025 calibration certificates are available upon request.

Q: What is the lead time for customized high-voltage hipot systems?

A: Standard dry-type and oil-immersed models (up to 50 kV / 10 kVA) ship within 7-10 business days. Custom engineering designs (above 100 kV, automated PLC test rigs, or multi-channel acquisition) typically require 3-4 weeks for manufacturing and factory testing.

 

modular-1
Request a Technical Quote

Need a tailored hipot testing system for your production line or testing facility? Provide your testing parameters below, and our application engineers will send technical drawings and pricing within 24 hours.

Required Test Voltage (kV): [ AC / DC ]
Specimen Type: [ Transformer / Cable / Switchgear / Motor / Other ]
Power Supply Specification: [ Voltage / Frequency ]
Control System Preference: [ Manual Dial / PLC Touchscreen / Computer Automated ]

Contact Email: wang@transformer-test.com
Technical Support Line: +8616630291792
Factory Location: Mancheng District, Baoding City, China

 

Refine On (Hebei) Electric Power Technology Co., Ltd. is one of the most reliable hipot tester manufacturers and suppliers in China, also supports customized service. Please feel free to wholesale advanced hipot tester at competitive price from our factory. Contact us for quotation.

Smart DC Withstand Voltage Tester, Intelligent HV DC Test Set, Intelligent Digital DC Hipot Tester
Send Inquiry