Refine On (Hebei) Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of dc high voltage generator in China. If you're going to wholesale durable dc high voltage generator, welcome to get quotation from our factory. All customized products are with high quality and competitive price.
Application Scenarios
The DC High Voltage Generator performs insulation performance tests after equipment is shipped, accepted, periodically tested, and after major overhauls to check its quality. The principle is to simulate overvoltages that the equipment may encounter during operation, expose potential hazards in advance, and then carry out targeted treatment to prevent sudden power outages or more dangerous accidents during normal operation.

Voltage Class & Model
|
Model |
Rated Voltage |
Rated Current |
Control Box Size (mm) |
Control Box Weight (kg) |
HV Unit Size (mm) |
HV Unit Weight (kg) |
|
NRG60 |
60 kV |
2–10 mA |
310 × 250 × 240 |
7 |
470 × 260 × 450 |
5 |
|
NRG80 |
80 kV |
2–10 mA |
310 × 250 × 240 |
7 |
470 × 260 × 450 |
5 |
|
NRG100 |
100 kV |
2–5 mA |
310 × 250 × 240 |
7 |
470 × 260 × 450 |
5 |
|
NRG120 |
120 kV |
2–5 mA |
310 × 250 × 240 |
7 |
470 × 260 × 450 |
6 |
|
Other models are available upon inquiry |
||||||
Technical Parameters
|
Parameter |
Value |
|
Output Polarity |
Negative |
|
Start Interlock |
Zero-voltage start (knob must be at zero) |
|
Voltage Adjustment |
Linear continuous |
|
Power Supply |
50 Hz, AC220V ±10% |
|
Voltage Accuracy |
±0.5% of reading ±2 digits, resolution 0.1 kV |
|
Current Accuracy |
±0.5% of reading ±2 digits, control box resolution 1 µA, external micro-ammeter resolution 0.1 µA |
|
Ripple Factor |
<0.5% |
|
Duty Cycle |
Intermittent, ≤30 minutes at rated load |
|
Operating Temp. |
0°C to 40°C |
|
Operating Humidity |
<90% RH |
|
Storage Temp. |
-10°C to 40°C |
|
Storage Humidity |
<90% RH |
|
Max. Altitude |
3000 m |
Features
Employs full-range linear and smooth voltage adjustment with an accuracy better than 0.1%, and voltage and current accuracy down to 0.5%
01
The high-voltage multiplier cylinder is encapsulated in all-solid state using DuPont materials, ensuring convenient operation, high safety, and lighter weight than oil-filled devices
02
Features discharge protection, with overvoltage setting functionality for cable testing and other electrical equipment testing, displaying the overvoltage value during adjustment
03
Includes an MOA voltage conversion button, allowing one-button testing of leakage current at 75% voltage without manual adjustment
04
FAQ
Q: What does the parameter 120kV/5mA mean on a DC High Voltage Generator?
A: 120 represents the rated output voltage, with a maximum output of 120kV. 5mA represents the rated output current; when the equipment outputs 120kV high voltage, it can continuously provide a maximum current of 5mA.
Q: What parameters of DC high voltage generator should be used for a 17kV zinc oxide surge arrester?
A: 60kV~80kV is acceptable. Generally, the voltage should be 3-5 times the rated voltage of the equipment.
Q: When using a DC high voltage generator for cable testing, why is it recommended to use a current of 5mA or higher?
A: Cable withstand voltage depends on cable length and voltage rating; using a higher current will allow for faster testing.
Hot Tags: dc high voltage generator, China dc high voltage generator manufacturers, suppliers, factory, 5kVA 100kv Frequency AC Hipot Tester, 5kVA 50kv Frequency AC Hipot Tester, Frequency AC Hipot Set, Hipot Voltage Phasing Tester, Intelligent Digital DC Hipot Tester, substation high potential tester