5kVA/100kv Frequency AC Hipot Tester

Send Inquiry
5kVA/100kv Frequency AC Hipot Tester
Details
The NR810D 5kVA/100kV Frequency AC Hipot Tester is a high-voltage AC/DC withstand voltage testing device featuring a compact, multi-level insulated structure to prevent oil leakage and reduce volume.
Category
Hipot Tester
Share to
Description

Refine On (Hebei) Electric Power Technology Co., Ltd. is one of the leading manufacturers and suppliers of 5kva/100kv frequency ac hipot tester in China. If you're going to wholesale durable 5kva/100kv frequency ac hipot tester, welcome to get quotation from our factory. All customized products are with high quality and competitive price.

 

The NR810D 5kVA/100kv Frequency AC Hipot Tester is a specialized test transformer designed for AC and DC high-potential testing. It utilizes an advanced "distance effect" multi-oil-channel insulation design and an integrated oil reservoir within the casing to enhance insulation integrity, eliminate traditional oil leakage issues, and ensure reliable high-voltage safety testing.

 

Product Specifications

 

Product ex-factory inspection report

Model: 100-5 NO: 251024

Detection result

Input voltage: 200V

Input current: 25A

Output voltage: AC: 0-100KV DC:0-140KV

Output current: 50mA

Insulation resistance (2500V GEU meter)

High pressure -ground: 2,500МΩ

Instrument--ground: 2500 МΩ

Low pressure- -ground: 2,500 МΩ

Variable ratio detection

High voltage-instrument: 1000:1

Highpressure-low pressure: 500:1

No-load test

Input voltage: 200V

Output voltage: AC: 0-100KV DC:0-140KV

No-load current:0.9A

Short-circuit test

Input current: 25A

Output voltage: 18V

Impedance voltage: 9%

Conclusion: Qualified permit factory

 

Addendum: The DL-32 current setting meter

Graduation Specifications

2.5

3

3.5

4

4.5

5

30/5A

15

18

21

24

27

30

40/5A

20

24

28

32

36

40

50/5A

25

30

35

40

45

50

60/5A

30

36

42

48

54

60

75/5A

37.5

45

52.5

60

67.5

75

100/5A

50

60

70

80

90

100

125/5A

62.5

75

87.5

100

112.5

125

150/5A

75

90

105

120

135

150

200/5A

100

120

140

160

180

200

250/5A

125

150

175

200

225

250

300/5A

150

180

210

240

270

300

 

Product Advantages

 

  • Leak-Proof Structural Design: Solves the oil expansion leakage issue common in traditional TDM series transformers by integrating the oil reservoir directly into the high-voltage casing.
  • Enhanced Insulation & Compact Size: Employs multi-level insulation based on the "distance effect" principle, significantly improving dielectric strength while reducing overall volume and weight.
  • Elimination of Internal Discharge: Utilizes metal fixed leads and pressure clamping mechanisms to prevent partial discharge and ensure stable high-voltage output.

 

Application Scenarios

 

  • Power Equipment Withstand Voltage Testing: Used for conducting AC or DC high-potential tests on power cables, switchgear, and transformers to verify insulation integrity per industry safety standards.
  • Electrical Component Dielectric Verification: Suitable for testing the breakdown voltage and leakage current of insulators, bushings, and other high-voltage components in manufacturing quality control.
  • Laboratory High-Voltage Research: Ideal for research institutions and testing labs requiring a stable and portable 100kV AC/140kV DC power source for experimental setups.
product-800-513

 

Selection Table

 

product-2452-2692

Related Products

 

product-1060-975

 

Factory Show

 

001
product-800-600
001
IMG20251022103948001
IMG20251022103740001
001
d9900876-46d8-4559-8cfe-00b19e625428001
001

 

Frequently Asked Questions (FAQ)

 

Q: What is the maximum DC voltage 5kVA/100kv Frequency AC Hipot Tester can generate, and what special precautions are required for DC operation?

A: This unit generates up to 140kV DC. During DC testing, you must loosen and insulate the short-circuit rod (D) inside the high-voltage casing and add an external current-limiting resistor and filter capacitor to prevent damage to the internal silicon stack.

Q: What are the specific insulation resistance values that this unit meets according to the factory inspection report?

A: According to the factory test report using a 2500V megohmmeter, the insulation resistance is 2,500 MΩ for High Voltage-to-Ground, Instrument-to-Ground, and Low Voltage-to-Gro.

 

Hot Tags: 5kva/100kv frequency ac hipot tester, China 5kva/100kv frequency ac hipot tester manufacturers, suppliers, factory, automated dc high voltage tester, hipot tester, Hipot Circuit Breaker Tester, High Voltage Circuit Breaker Tester, HV Phasing Tester, dc hipot test set