DC High Voltage Tester• Model: NRG60/80/100/120 DC High Voltage Tester . • Adopts high-frequency PWM closed-loop regulation for stable output.. • Output voltage range: 60 kV / 80 kV / 100 kV / 120 kV (model-dependent),
-
Smart Dc High Voltage TesterThe NRG60Z/80Z/ 100Z/120Z Smart DC High Voltage Tester series is designed for DC withstand voltage and preventive insulation testing. . Key features include:. • 7-inch 800×480 full-color touchscreen
-
5kVA/50kv Frequency AC Hipot TesterThe NR801D 5kVA/50kV Frequency AC Hipot Tester is designed for insulation withstand voltage testing. Key features include:. • Compact structure based on multi-layer insulation technology.. •
-
5kVA/100kv Frequency AC Hipot TesterThe NR810D 5kVA/100kV Frequency AC Hipot Tester is a high-voltage AC/DC withstand voltage testing device featuring a compact, multi-level insulated structure to prevent oil leakage and reduce volume.
-
Hipot Circuit Breaker TesterNRG400 Hipot Circuit Breaker Tester is a high-voltage switch mechanic characteristic analyzer, capable of simultaneously measuring 12 metal contact fractures and providing adjustable DC20–270V
-
Hipot Voltage Phasing TesterThe NR-HX36 Hipot Voltage Phasing Detector features a safe wireless transmission distance of over 130 meters and provides clear phase differentiation with voice prompts and visual waveform/vector
WEBDC withstand testing DC overvoltage testing (also known as withstand testing) is the most popular method of general condition and integrity assessment in the power, industrial, and domestic...
WEBWrap the instrument in a bubble pack or similar foam. Enclose the same information as above. Use a strong double-wall container that is made for shipping instrumentation. 350 lb. test material is...
WEBDec 7, 2018 · The BDV is the voltage where the part arcs across the metallic interface; think pin-to-pin or pin-to-hardware, and working voltage is = 1/3 x DWV or 0.25 x BDV. For example: if the...
WEBIn addition to the basic AC Withstanding test, the GPT-815 also features DC Withstanding testing and the GPI-825/826 feature Insulation Resistance testing. With a 500VA of AC capacity for the...
WEBAug 15, 2022 · As stated above, dielectric breakdown occurs following exposure of the insulation material to an exceptionally high voltage. One test required in many UL standards is a Dielectric...
WEBMar 7, 2018 · An AC test voltage of 1000 Vrms will have voltage peaks of 1414 Volts. Therefore, if a DC test voltage is used, the test voltage must...